Imperial/Infector Detector/F2620 Comparison

From 2007.igem.org





Summary of Comparison

We thought to compare our in vitro characterisation to the characterisation of F2620 in vivo with the aim to highlight some of the differences between the chassis and investigate how the construct's characteristics may change between them. The F2620 is an ideal construct for comparison because of its detailed characterisation in vivo. The construct is the same as the construct 1 that was used for infecter detector, pTet-LuxR-pLux-GFPmut3b.

The key results of the comparison were:

  • The creation of a new unit to allow comparison between in vitro and in vivo chassis.
  • The response of the construct in E.coli chassis in vivo and in vitro is independent of the chassis

These are exciting findings, revealing the potential for the exploration of new chassis and the ability to use constructs in an exchangeable manner.



IC2007 BF stage1 construct.PNG

The basis for comparison is to normalise the in vitro chassis on the number of plasmids to give a platform for comparison:
  • In Vitro - 4µg of DNA was added which for pTet-LuxR-pLux-GFPmut3b is 904823007 plasmids
  • In Vivo - Each cell the plasmids number was estimated at 200 per cell

To compare we normalised the data of in vitro GFPmut3b molecules synthesised per 200 plasmids to allow some comparison to the in vivo data.

Of particular interest was to compare the:

  1. Rate of GFP synthesis of 100nM AHL
  2. Transfer Function- [AHL] vs rate of GFP synthesis


In vitro in vivo comp.png
Comparison between in vivo and in vitro for rate of GFPmut3b synthesis for 100nM AHL. The in vivo chassis used was the bacterial strain MG1655 and the in vitro chassis was Promega Commercial S30 Cell Extract(60µl)


The graph shows the following:

  • in vivo has a maximal rate of 400-500 molecules of GFP synthesised per second per cell. In addition the rate reaches a steady state after 30minutes.
  • in vitro has the equivalent of 1400 molecules of GFP synthesised per second per 200 plasmids. Interestingly the in vitro chassis does not reach a steady state, in fact it decreases in rate of synthesis after 90 minutes and keeps decreasing until rate is zero at around 360 minutes. This is thought to be because the in vitro chassis runs out of energy after 90 minutes, because of this rate slowly decreases.

Key Difference:

  • GFP Synthesis - The life of synthesis of in vitro is about 90 minutes, compared to in vivo that has a life span of days. The differences is that in vitro has a burst of expression giving a high but short rate of GFP synthesis. In vivo is a slower rate but more prolonged rate of synthesis.
  • Initial Rate of Synthesis - The initial rate of GFP synthesis is slower for in vitro. This is thought to be due to LuxR levels, which inin vivo can reach steady state before the addition of AHL, in in vitro LuxR is only produce upon addition of DNA meaning that it cannot reach high levels before addition of AHL.

Interestingly the values of rate of synthesis are in the same order magnitude of hundreds, this suggesting that the normalisation we are using to compare these chassis is valid.


Comparison of transfer function.PNG
The graph above shows the transfer function of [AHL] input vs rate of GFP synthesis output. The graph shows the follwoing:
  • in vivo(blue line) max rate of synthesis which is the steady state that is reached after about 30 minutes
  • in vitro(red line) max rate of synthesis which is the rate between 60 and 90 minutes which is the maximum rate before the energy limitations of the system cause the rate to drop. The dotted red line represents the expected transfer function for the lower AHL concentrations that we did not collected data points for.


Key Difference:

  • Shape of Transfer Function- a sigmoidal shaped transfer function with a step linear region flanked by a lower threshold and upper threshold is seen for both chassis. This indicates that the characteristic response of the construct is independent of the chassis for a given strain i.e both of these in vitro and in vivo chassis are from E.coli.
  • Rate of GFP Synthesis - The rate of synthesis is greater in the in vitro chassis e.g. for 1000nM AHL the rate is 1400 GFP molecules synthesis per second per cell equivalent for in vitro, and 500 GFP molecules synthesis per second per cell. This makes sense because the commercial E.coli cell extract we use is optimised for protein synthesis.
  • Upper Threshold - The upper threshold of response looks as if it occurs at ~1000nM for both chassis. The saturation is due to the saturation of expression equipment, meaning that the system cannot respond to any increase to AHL.
  • Lower Threshold - The lower threshold of response is 1nM for in vivo, however because of the lack of data points we had to extrapolate this for in vitro. From the shape of the in vitro data we collected, it seems the threshold could be at a higher concentration of AHL, meaning that the in vitro chassis is less sensitive to lower AHL concentrations. However without these data points it is difficult to define this threshold accurately.
<< Testing | F2620 Comparison| Conclusions >>