- Applications:
- Identification of insert presence
- Time to complete protocol:
- Lab time: 15min, 15min.
- Waiting time: 1-3hours
- Approximate cost of materials: $0.00
Method from primary and secondary reagents
Primary & secondary Reagents Required including controls
- Restriction enzymes and buffer
- BSA
- DNA for digestion
- milliQ water
- Loading dye for DNA gel
Method including controls
For 20uL reation volume
- Make the following reaction mixture on ice.
- Reaction Mixture
- 0.5uL Enzyme 1
- 0.5uL Enzyme 2
- Add enzymes last only take out of the freezer once ready to add.
- 2uL appropriate 10x buffer (see table on fridge)
- 2uL 10x BSA
- 10uL milliQ water
- 5uL DNA
- If performing the same digest for multiple DNA samples make up mastermix of buffer enzyme soultion and make 15uL aliquots to which to add the DNA.
- Volume DNA may vary depending on concentration, vary water volume to achieve 20uL reaction volume.
- Reaction Mixture
- Incubate for 1-3 hrs at 37 degrees.
- Stop reaction with addition of 5uL 6x DNA Loading dye.
- Can be stored at -20 or run on gel immediately.
Equipement Required
- microcentrifuge: 1.7ml
- Ice box and ice
- 37 degree incubator
- Pipettes and Tips
References