Imperial/Wet Lab/Lab Notebook/2007-10-05
From 2007.igem.org
(Difference between revisions)
Line 5: | Line 5: | ||
+ | ==pTet-LuxR-pLux-GFP construct in-vivo== | ||
+ | *'''Aim''': The aim of the test was to check if construct 1 of infector detector works in-vivo | ||
+ | *The protocols for the experiment can be found [[IGEM:IMPERIAL/2007/Wet Lab/Protocols/ID1.1|here]] | ||
+ | *The [[IGEM:IMPERIAL/2007/new pages/in vivo|results]] of the test showed that pTet-LuxR-pLux-GFPmut3b is working in vivo and GFPmut3b produced increases with increasing [AHL] | ||
+ | |||
+ | ==pTet-LuxR-pLux-GFP construct in-vitro== | ||
+ | *'''Aim''': The aim of the test was to check if construct 1 of infector detector works in-vitro, for a number of concentrations of AHL | ||
+ | *The protocols for the experiment can be found [[IGEM:here|here]] | ||
+ | *The [[Media:IC 2007 PLux in-vitro 05-10 25oC.xls|results]] of the test seemed very variable and didn't seemed to comply with the tests that were carried out before. There was a lot of variability between the samples and 4nM of AHL seemed to have fluorescence output greater than 50nM. | ||
+ | *It was decided to carry out the experiment again. The reasons for the inaccuracies in the data could have been: | ||
+ | **The reaction was not mixed properly or the right amounts were not pipetted | ||
+ | **The plates had already been used and thus could have affected the reaction | ||
<html></div></html> | <html></div></html> | ||
{{Template:IC07labnotebook}} | {{Template:IC07labnotebook}} |
Revision as of 19:43, 24 October 2007
5 October 2007
pTet-LuxR-pLux-GFP construct in-vivo
- Aim: The aim of the test was to check if construct 1 of infector detector works in-vivo
- The protocols for the experiment can be found here
- The results of the test showed that pTet-LuxR-pLux-GFPmut3b is working in vivo and GFPmut3b produced increases with increasing [AHL]
pTet-LuxR-pLux-GFP construct in-vitro
- Aim: The aim of the test was to check if construct 1 of infector detector works in-vitro, for a number of concentrations of AHL
- The protocols for the experiment can be found here
- The results of the test seemed very variable and didn't seemed to comply with the tests that were carried out before. There was a lot of variability between the samples and 4nM of AHL seemed to have fluorescence output greater than 50nM.
- It was decided to carry out the experiment again. The reasons for the inaccuracies in the data could have been:
- The reaction was not mixed properly or the right amounts were not pipetted
- The plates had already been used and thus could have affected the reaction