Week 12

From 2007.igem.org

(Difference between revisions)
 
(One intermediate revision not shown)
Line 64: Line 64:
::7. The bacteria with [http://partsregistry.org/Part:BBa_I763019 I763019] plasmid doesn’t beam fluorescence with (A2, B2) nor without (A1, B1)  IPTG;  
::7. The bacteria with [http://partsregistry.org/Part:BBa_I763019 I763019] plasmid doesn’t beam fluorescence with (A2, B2) nor without (A1, B1)  IPTG;  
::8. Very few bacteria with [http://partsregistry.org/Part:BBa_I7630231 I763031] plasmid with (C2) and without (C1) IPTG beam fluorescence.  
::8. Very few bacteria with [http://partsregistry.org/Part:BBa_I7630231 I763031] plasmid with (C2) and without (C1) IPTG beam fluorescence.  
-
*In conclusion, we see that bacteria with [http://partsregistry.org/Part:BBa_I763019 I763019] plasmid (tubes A1, B1, A2, B2) don't seem to work at all, and bacteria with I763031 plasmid (tube C1, C2) don't seem to work properly either. We plan other experiments for next week.
+
*In conclusion, we see that bacteria with [http://partsregistry.org/Part:BBa_I763019 I763019] plasmid (tubes A1, B1, A2, B2) don't seem to work at all, and bacteria with [http://partsregistry.org/Part:BBa_I763031 I763031] plasmid (tube C1, C2) don't seem to work properly either. We plan other experiments for next week.
Line 74: Line 74:
-
[[Bologna | Back]]
+
[[Bologna#Diary | Back]]

Latest revision as of 15:52, 26 October 2007

09/17/07
  • Ligations for:

-[http://partsregistry.org/Part:BBa_I763026 I763026] + [http://partsregistry.org/Part:BBa_I763019 I763019];

-[http://partsregistry.org/Part:BBa_I763026 I763026] + [http://partsregistry.org/Part:BBa_I763004 I763004];

-[http://partsregistry.org/Part:BBa_I763025 I763025] + [http://partsregistry.org/Part:BBa_J04031 J04031].

  • We transform ligations and strake them on plates.


09/18/07
  • We inoculate a colony for yesterday ligations in 5ml of LB medium O/N.


09/19/07
  • Miniprep for:

-[http://partsregistry.org/Part:BBa_I763028 I763028];

-[http://partsregistry.org/Part:BBa_I763027 I763027];

-[http://partsregistry.org/Part:BBa_I763035 I763035] (Spe/Pst1), (Xba/Pst1).

  • Digestion for:

-[http://partsregistry.org/Part:BBa_I763028 I763028] with Eco/Spe;

-[http://partsregistry.org/Part:BBa_I763027 I763027] with Eco/Spe;

-[http://partsregistry.org/Part:BBa_I763035 I763035] with Eco/Spe;

-[http://partsregistry.org/Part:BBa_I763007 I763007] with Eco/Xba;

-[http://partsregistry.org/Part:BBa_I763036 I763036] with Eco/Spe1;

  • Band extraction from gel for all digestion and then we observe:

-[http://partsregistry.org/Part:BBa_I763028 I763028], [http://partsregistry.org/Part:BBa_I763027 I763027] are died;

-[http://partsregistry.org/Part:BBa_I763035 I763035] is correct;

-[http://partsregistry.org/Part:BBa_I763007 I763007] not found;

-[http://partsregistry.org/Part:BBa_I763036 I763036] is correct.


09/20/07

Testing our devices

We wanted to test if our newly-constructed devices work, that is if they beam fluorescence when inducted with IPTG. To do so we performed 3 tests in parallel in 3 different tubes, that we name here A, B and C.

1. In tube A e in tube B we add 5ml of LB medium and 2 different colonies of [http://partsregistry.org/Part:BBa_I763019 I763019] plasmid.
2. In tube C we add 5ml of LB medium and a colony of [http://partsregistry.org/Part:BBa_I763031 I763031] plasmid.
3. After 2 hours we measure the OD value of tubes A, B, C and it is around 0.5.
4. For tubes A, B, C we divided the bacteria fluid in two different tubes A1, A2; B1, B2; C1, C2.
5. We add 1mM IPTG to the solution into tubes A2, B2, C2.
  • The analyzed fluid without IPTG (tubes A1, B1, C1) includes:
-2.5ml of original tube fluid;
-2.5ml of LB medium;
-2.5ul of kanamicin.
  • The analyzed fluid with IPTG (tube A2, B2, C2) includes:
-2.5ml of original tube fluid;
-2.5ml of LB medium;
-2.5ul of kanamicin;
-50ul of 100mM IPTG.
6. We examine a bacteria fluid drop of tubes A1, A2, B1, B2, C1, C2 with our fluorescence microscope.
7. The bacteria with [http://partsregistry.org/Part:BBa_I763019 I763019] plasmid doesn’t beam fluorescence with (A2, B2) nor without (A1, B1) IPTG;
8. Very few bacteria with [http://partsregistry.org/Part:BBa_I7630231 I763031] plasmid with (C2) and without (C1) IPTG beam fluorescence.
  • In conclusion, we see that bacteria with [http://partsregistry.org/Part:BBa_I763019 I763019] plasmid (tubes A1, B1, A2, B2) don't seem to work at all, and bacteria with [http://partsregistry.org/Part:BBa_I763031 I763031] plasmid (tube C1, C2) don't seem to work properly either. We plan other experiments for next week.



09/21/07

Meeting: definition of fluorescence test protocol.


Back