* design: 5 tubes for 0%, 1%, 3%, 5%, 10% extra glucose cultured in LB medium
* design: 5 tubes for 0%, 1%, 3%, 5%, 10% extra glucose cultured in LB medium
* tube with 0% extra glucose is treated as negative control
* tube with 0% extra glucose is treated as negative control
 +
* 20% glucose solution
{| align=center | border=1 | style="text-align:center"
{| align=center | border=1 | style="text-align:center"
!glucose (%)
!glucose (%)
Line 28: Line 29:
!white light
!white light
!green light
!green light
 +
!LB volume
 +
!glucose volume
|-
|-
|0
|0

Revision as of 10:46, 28 September 2007

CinR+HSL+D-term check

  • After re-culture in 20-block plate,randomly pick 6 blocks from CinR+HSL+D-term plate
  • PCR check using VF2, VR primers
  • PCR total 50 uL, 10 uL for GEL separation
  • sample at each lane
    • 1Kb ladder
    • block #1 (insert band appears)
    • block #2 (insert band appears, and one extra band around 400 bp)
    • block #3 (insert band appears)
    • block #4 (insert band appears)
    • block #5 (insert band does not appear, only band around 400 bp)
    • block #6 (insert band does not appear, only band around 400 bp)
  • expect results: one band at 1,623 bp is our insert
    • insert = RBS+CinR (2,843 - 2,053) + RBS+HSL (2,783 - 2,053) + D-term (3,266 - 3,163)
    • insert = 790 + 730 + 103 = 1,623
  • extra band at 400 bp might be plasmid failed to be correctly ligated
    • PCR product length without any insert = (3,189 - 3,049) + 176 = 316
  • References
    • [http://partsregistry.org/Image:PsB1AK3_map.jpg vector map of pSB1AK3 and VF2 VR primers]

NYMU Taipei 20070927 CinR-HSL-D-term plate culture test.jpg


pOmpC glucose response testing by construct (pOmpC + EYFP)

  • design: 5 tubes for 0%, 1%, 3%, 5%, 10% extra glucose cultured in LB medium
  • tube with 0% extra glucose is treated as negative control
  • 20% glucose solution
glucose (%) O.D. 600 white light green light LB volume glucose volume
0 2.487 NYMU Taipei pOmpC-EYFP 0p-w.JPG NYMU Taipei pOmpC-EYFP 0p-g2.JPG
1 2.091 NYMU Taipei pOmpC-EYFP 1p-w.JPG NYMU Taipei pOmpC-EYFP 1p-g3.JPG
3 1.861 NYMU Taipei pOmpC-EYFP 3p-w.JPG NYMU Taipei pOmpC-EYFP 3p-g.JPG
5 1.637 NYMU Taipei pOmpC-EYFP 5p-w.JPG NYMU Taipei pOmpC-EYFP 5p-g.JPG
10 1.025 NYMU Taipei pOmpC-EYFP 10p-w.JPG NYMU Taipei pOmpC-EYFP 10p-g.JPG