Imperial/Wet Lab/Protocols/CE1.5
From 2007.igem.org
Contents |
Equipments
Equipments
- Fluorometer + PC
- 1 Fluorometer plate (black)
- Sticky seal tape
- Gilson pipettes p200 p20 p10
- Eppendorf Tubes
- Stopwatch
Reagents
- Pyruvate kinase
- rNTPs
- S30 cell extract (home made)
- Reaction buffer (home made)
- Commercial S30 E.coli extract. Including:
- 175µl Amino Acid Mixture Minus Cysteine, 1mM
- 175µl Amino Acid Mixture Minus Methionine, 1mM
- 175µl Amino Acid Mixture Minus Leucine, 1mM
- 450µl S30 Extract, Circular (3 × 150µl)
- 750µl S30 Premix Without Amino Acids
- Nuclease Free water
- DNA pTet-LuxR-pLux-GFP from midiprep
Steps
- Fill an eppendorf tube with two samples (56ul x 2) of home made cell extract including reaction buffer, pyruvate kinase and rNTPs.The volumes are shown below:
- Home made S30 - 16.2ul
- Reaction Buffer- 30ul
- rNTP's - 1ul
- Pyruvate Kinase - 3.1ul
- DNA - 4ul
- ddH2 - 5.7ul
- Fill a second eppendorf tube with two samples (40ul x 2) of commercial cell extract including the amino acids mixture, and preincubation buffer.
- Place a quarter of each mixture in a well in the 96 well plate, making up 2 wells (B3 and B5).
- In another well (C4), as a control, place another quarter of only the commercial cell extract, with 28ul of water.
- In the last well (D5), add a quarter of each mixture. This serves as the negative control.
- In the last well, add nuclease free water (again as a negative control).
- In wells B3, B5 and C4, add 20ul of DNA.
- Measure the fluorescence at 30 min intervals for the 1st hour, and hourly intervals thereafter.
- After each measurement, cover the plate with the sticky lid.