Imperial/Cell by Date/Testing

From 2007.igem.org

(Difference between revisions)
m (Investigation System properties under Dynamic Temperature Conditions)
m (Investigation System properties under Dynamic Temperature Conditions)
Line 46: Line 46:
*In terms of lifespan we have had major problems with evaporation meaning that the lifespan of our system is limited to a few days. <br>
*In terms of lifespan we have had major problems with evaporation meaning that the lifespan of our system is limited to a few days. <br>
-
===Investigation System properties under Dynamic Temperature Conditions===
 
-
[[Image:IC 2007 CBD steps.PNG|600px|center|thumb|Fig 1.1:Average fluorescence over time for two samples at constant temperatures of 4&degC and 20&deg;C and two with a temperature step (4-20&deg;C and 20-4&deg;C)]]
 
-
<br clear ="all">
 
-
 
-
Response time extraction still to do
 
==Validation and Conclusion==
==Validation and Conclusion==

Revision as of 20:29, 26 October 2007



Cell by Date: Testing

Testing and Discussion

Investigation properties of system under isothermal scenarios

To estimate the properties of our system we looked at the evolution of the Fluorescence with time for experiments where temperature is carefully kept constant. (Figure 1).
General Behaviour:

  • In all experiment we can observe a linear growth of fluorescence corresponding to a steady rate of protein production.
  • This matches the claims of the manufacturer of the cell-free extract that the extract is optimised so that protein degradation is negligible.

Isothermal Data

Operating Range:

  • Our system seems to 'turn off' at around 4 degrees C.
  • At 8 degrees with have minimal expression which then increases to a substantial expression at 37 degrees.

Synthesis rate vs Temperature

  • Over the range of temperature considered here the rate increases with temperature.
  • To investigate the relation between synthesis rate and temperature we extracted the rate of synthesis of GFP for each experiment and plotted it against 1/T (Figure 2).
  • A strong linear correlation in the log plot supports an arrhenius type dependence on temperature with an activation energy of 1.5kJ/mol.

Arrhenius Plot

Other practical considerations:

  • Unfortunetly we have not been able to use a visible reporter and so have no idea whether the construct can in fact produce a visible signal.
  • In terms of lifespan we have had major problems with evaporation meaning that the lifespan of our system is limited to a few days.


Validation and Conclusion

<< Implementation | Testing/Validation | Conclusions >>