Cell by Date: Testing

Summary

Key results of our experiments are :

1.Operating Range : Our System Operates between 8-37 Degrees
2.Activation Energy : The activation energy of our system is 1.5kJ/mol
3.Optimum DNA Concentration : The optimum DNA concentration for our system is 2-4ug DNA

Aims

Having determined that our system worked at a basic level in our implementation phase we set out to ascertain a clearer picture of the performance of our system to ultimately reveal whether our design had realised our specifications.

Results

Investigating properties of system under isothermal scenarios

To estimate the properties of our system we looked at the evolution of the Fluorescence with time for experiments where temperature is carefully kept constant. (Figure 1).
General Behaviour:

  • In all experiment we can observe a linear growth of fluorescence corresponding to a steady rate of protein production.
  • This matches the claims of the manufacturer of the cell-free extract that the extract is optimised so that protein degradation is negligible.
Figr 1:Isothermal Data - Averages GFPmut3b molecules synthesised for pTet-GFPmut3b construct at different temperatures

Operating Range:

  • Our system seems to 'turn off' at around 4 degrees C.
  • At 8 degrees with have minimal expression which then increases to a substantial expression at 37 degrees.

Synthesis rate vs Temperature

  • Over the range of temperature considered here the rate increases with temperature.
  • To investigate the relation between synthesis rate and temperature we extracted the rate of synthesis of GFP for each experiment and plotted it against 1/T (Figure 2).
  • A strong linear correlation in the log plot supports an arrhenius type dependence on temperature with an activation energy of 1.5kJ/mol.
Fig 2: Arrhenius Plot

Need to put link here to wet lab page where i give full analysis of activation energy

Other practical considerations:

  • Unfortunetly we have not been able to use a visible reporter and so have no idea whether the construct can in fact produce a visible signal.
  • In terms of lifespan we have had major problems with evaporation meaning that the lifespan of our system is limited to a few days as discussed in our packaging experiment below.

Investigating properties of system under dynamic temperature scenarios

As per our specifications we are not only interseted in how our system behaves under isothermal scenarios but also under dynamic temperature scenarios representative of a break in the cold chain for example.

Below in figure 3 are the results from one of our experiments in which we subjected our system to a number of steps.

Fig 3:Molecules of GFPmut3b produced on average over time for two samples at constant temperatures of 4&degC and 20°C and two with a temperature step (4-20°C and 20-4°C)

General Behaviour :

  • Step Down from 20 to 4 Degrees : Rate of fluoresence decreases in comparison to the 20 degree isothermal curve. This is a positive result as it correlates with Koutsoumanis' meat model in our modelling section.
  • Step Up from 4 to 20 Degrees : Rate of fluoresence increases rapidly in comparison to the 20 degree isothermal curve. This is a positive result as it correlates with Koutsoumanis' meat model in our modelling section in which the response time of spoilage bacteria in beef is very small.

Other Experiments

1. DNA Concentration

2. Packaging



<< Implementation | Testing/Validation | Conclusions >>