+ | ==Optimum DNA concentration== | ||
+ | *Aim today was to get the optimum DNA concentration for the pTet-GFP and the pTet-lixR-pLux-GFP construct. | ||
+ | *The constructs were tested for 0, 1, 2, 4 and 6ug of DNA. | ||
+ | *The fluorescence over a period of 6 hours was recorded every hour for all the concentrations. | ||
+ | *It was found that at 25°C pTet-lixR-pLux-GFP behaves as expected, i.e. the optimum output is for a mass between 2 and 4ug of DNA. | ||
+ | *For pTet-GFP construct, at 37°C, the fluorecence was highest at the end of the day for 6ug of DNA. | ||
<html></div></html> | <html></div></html> | ||
{{Template:IC07labnotebook}} | {{Template:IC07labnotebook}} |
Latest revision as of 14:13, 10 October 2007
28 September 2007
Optimum DNA concentration
- Aim today was to get the optimum DNA concentration for the pTet-GFP and the pTet-lixR-pLux-GFP construct.
- The constructs were tested for 0, 1, 2, 4 and 6ug of DNA.
- The fluorescence over a period of 6 hours was recorded every hour for all the concentrations.
- It was found that at 25°C pTet-lixR-pLux-GFP behaves as expected, i.e. the optimum output is for a mass between 2 and 4ug of DNA.