Imperial/Infector Detector/Modelling
From 2007.igem.org
Line 70: | Line 70: | ||
===='''1.'''==== | ===='''1.'''==== | ||
- | [[Image: | + | [[Image: C1 GFP AHL.png |left|thumb|<b>Fig. 3</b>: Plot of [GFP] vs time for [AHL]<sub>0</sub> = 0.1nM, 1nM, 10nM & 100nM| 435px]] |
- | [[Image: | + | [[Image: C2 GFP AHL.png |right|thumb|<b>Fig. 4</b>: Plot of [GFP] vs time for [AHL]<sub>0</sub> = 0.1nM, 1nM, 10nM & 100nM| 440px]] |
====<center>Discussion</center>==== | ====<center>Discussion</center>==== | ||
---- | ---- | ||
+ | It is evident from the above figures, that the response time of construct 1 (C1) is far greater than that of construct 2 (C2). C1 crosses some arbitrary threshold at approximately t = 80min, whereas C2 below 10min. | ||
+ | This is in line with our hypothesis, as we know steady-state has been forced upon the system in case of construct 2 - by flooding the system with purified LuxR. | ||
+ | Also the peak expression (max output) of GFP obtained for C1 is lower by approximately 50 percent. So, C2 produces a stronger output for corresponding [AHL]. | ||
+ | However, although C2 is faster and generates a greater output, its energy consumption is far more pronounced. C1 thus has a greater lifespan. | ||
---- | ---- | ||
===='''2.'''==== | ===='''2.'''==== | ||
- | [[Image: | + | [[Image: IC07 TransferFnc comp.png|thumb|left|440px]] |
- | [[Image: | + | [[Image: IC07 TransferFnc2 comp.png|thumb|right|440px]] |
====<center>Discussion</center>==== | ====<center>Discussion</center>==== | ||
---- | ---- | ||
- | + | The two figures above illustrate the response of both constructs after a specific t value. For both cases, the transfer function of C2 remains constant. However for C1, the sensitive AHL range decreases as t decreases (figure right - high t, left - low t). This is in line with our previous observation, where C1 longer response time compared to C2. | |
- | This is in line with our | + | |
- | Also the | + | Also, it is clear that at lower concentrations of AHL, the output of both systems very close. As t increases, the concentration limit where both constructs have the same output can be increased by increasing t. This is because with more time, more LuxR is produced by C1 to allow a greater output compared to C2. |
- | + | ||
---- | ---- | ||
Line 129: | Line 131: | ||
---- | ---- | ||
- | |||
- | |||
Line 137: | Line 137: | ||
== Equations == | == Equations == | ||
- | + | Link to [[Imperial/Dry_Lab/Modelling#Model_1|Equations to Construct 1]] in our Dry Lab page. | |
- | + | Link to [[Imperial/Dry_Lab/Modelling#Model_2|Equations to Construct 2]] in our Dry Lab page. | |
=== Table of Parameters === | === Table of Parameters === | ||
- | + | Link to [[Imperial/Dry_Lab/Modelling#Model_Parameters|Table of Parameters]] in our Dry Lab page. | |
<center> [https://2007.igem.org/Imperial/Infector_Detector/Design << Design] | Modelling | [https://2007.igem.org/Imperial/Infector_Detector/Implementation Implementation >>] | <center> [https://2007.igem.org/Imperial/Infector_Detector/Design << Design] | Modelling | [https://2007.igem.org/Imperial/Infector_Detector/Implementation Implementation >>] | ||
</center> | </center> |
Revision as of 13:38, 23 October 2007
Jaroslaw Karcz. This is very confusing. A modelling page for infector detector and yet there is an entire section devoted to modelling, on the dry-lab drop-down menu. I have been working on ID there. I will continue to do so until I complete the modelling. See link below
Abstract
Formulation of the problem
As described earlier, catheter-associated urinary tract infection (CAUTI) in the clinical setting is a prevalent problem with extensive economic impact. The underlying cause of many such infections can be attributed to the formation of biofilm, by aggregating-bacteria on the surface of urinary catheters.
Infector Detector (ID) is a simple biological detector, which serves to expose bacterial biofilm. It functions by exploiting the inherent AHL (Acetyl Homoserine Lactone) production employed by certain types of quorum-sensing bacteria, in the formation of such structures.
Our project attempts to improve where previous methods of biofilm detection have proven ineffective: first and foremost, by focussing on the sensitivity of the system, to markers of biofilm: in this case, low levels of AHL production (which represents the bacterial "chatter" of such aggregating bacteria).
In doing so, a complete investigation of the level of sensitivity to AHL concentration needs to be performed - in other words, what is the minimal AHL concentration for appreciable expression of a chosen reporter protein. Furthermore, establish a functional range for possible AHL detection. How does increased AHL concentration impact on the maximal output of reporter protein?
Finally, how can the system performance be tailored, by exploiting possible state variables (e.g. varying initial LuxR concentration and/or concentration of pLux promoters).
The system performance here revolves most importantly around AHL sensitivity; however, the effect on the maximal output of fluorescent reporter protein and response time is, likewise, of great importance.
Establishing a model
Approach
At reasonably high molecular concentrations of the state variables, a continuous model can be adopted, which is represented by a system of ordinary differential equations.
It is for this reason that our approach to modelling the system follows a deterministic, continuous approximation. In developing this model, we were interested in the behaviour at steady-state, that is when the system has equilibrated and the concentrations of the state variables remain constant.
We can condition the system in various manners, but for the purposes of our project, we will seek a formulation which is valid for both constructs considered, i.e. the governing equations are a represenation of both constructs.
The only difference is with regards to the parameter k1, the maximum transcription rate of the constitutive promoter (pTET) in Construct 1.
Thus k1 = 0 for construct 2 (which lacks pTET).
Furthermore, we generate two models based upon the available system energy:
Model 1: Infinite Energy
Model 2: Limited Energy
The system kinetics are determined by the following coupled-ODEs. For a derivation of the governing equations, please access Model Derivation
Graphs/Simulations
Approach
Having generated the models for Infector Detector (applicable to both constructs) we intend to examine the behaviour of the system, w.r.t those state variables, which are experimentally manipulable.
Initially, we examine the behaviour of the system for a given set of parameters. Our immediate goal is to obtain some intuition about the system; data analysis will in due course provide us with more biologically plausible parameters. These can then be incorporated into the system model for a more representative output, which in turn allows for more realistic prediction/investigation. In other words, our initial approach is qualitative.
As described in the section on the development of the model, two models were established. However, these models are intimately connected. In fact, model 1 (link here), which is representative of the infinite energy case, is simply the limit case of the finite energy model, given by model 2. Model 2 approaches model 1, for greatly exaggerated initial energy (E0) and by setting the gene transcription cost, αi to zero.
Simulations are thus performed on the basis of the more representative model 2.
Investigations
The following simulations were performed for both constructs, unless explicitly stated:
- [GFP] vs [AHL] - transfer function curve
- [GFP] vs time - varying [AHL]0
- [GFP] vs time - varying [P]0
- [GFP] vs time - varying [LuxR]0 - Construct 2
Results
1.
Discussion
It is evident from the above figures, that the response time of construct 1 (C1) is far greater than that of construct 2 (C2). C1 crosses some arbitrary threshold at approximately t = 80min, whereas C2 below 10min. This is in line with our hypothesis, as we know steady-state has been forced upon the system in case of construct 2 - by flooding the system with purified LuxR.
Also the peak expression (max output) of GFP obtained for C1 is lower by approximately 50 percent. So, C2 produces a stronger output for corresponding [AHL]. However, although C2 is faster and generates a greater output, its energy consumption is far more pronounced. C1 thus has a greater lifespan.
2.
Discussion
The two figures above illustrate the response of both constructs after a specific t value. For both cases, the transfer function of C2 remains constant. However for C1, the sensitive AHL range decreases as t decreases (figure right - high t, left - low t). This is in line with our previous observation, where C1 longer response time compared to C2.
Also, it is clear that at lower concentrations of AHL, the output of both systems very close. As t increases, the concentration limit where both constructs have the same output can be increased by increasing t. This is because with more time, more LuxR is produced by C1 to allow a greater output compared to C2.
3.
Discussion
The above figures indicate the effect of increasing initial pLux promoter concentration ([P]0). The experiment involved varying ([P]0) and observing the concomitant effect on GFP expression. The following ([P]0) were utilized: 1, 2, 5, 10, 20 & 50nM.
It is clear that an increase in promoter concentration leads to reduction in response time (meaning that the same threshold is achieved in shorter time = more rapid response). This is a very prominent observation, particularly in the case of construct 1, in fig. x.
The increased promoter concentration also increases eventual maximum output of GFP = greater fluorescence = greater visual output. However, this effect is quite marginal. Evidently, this behaviour levels off (achieves saturation) with increased promoter concentration.
This behaviour is exhibited evidently in both constructs; however, the effect on C2 is quite interesting. Since we are increasing promoter concentration, there is increasing expenditure of energy. From previous analyses, we observed that for [P]0 = 5, saturating behaviour for C2 (when initial [LuxR] was adjusted) occurred at [LuxR] ~ 10nM. For this concentration, the energy expenditure, was quite extensive. So that for the corresponding time lapse, only about a fifth of initial energy content remained. In this experiment, the promoter concentration further depletes that energy, to such an extent that although a high expression peak (of GFP) is obtained (over 100000 arbitrary units), the lack of energy in the system, soon leads to degradation of [GFP] and visual output. For C1, even though the promoter concentration is increased to the same extent, there is still residual energy, and so degradation of signal does not occur on the same time-scale as for C2.
4
Discussion
Conclusions
Equations
Link to Equations to Construct 1 in our Dry Lab page. Link to Equations to Construct 2 in our Dry Lab page.
Table of Parameters
Link to Table of Parameters in our Dry Lab page.