We tested bacterial clones transformed with three different plasmids, [http://partsregistry.org/Part:BBa_I763004 I763004], [http://partsregistry.org/Part:BBa_I763035 I763035] and [http://partsregistry.org/Part:BBa_I763011 I763011], each of them grown into two different mediums, LB and M9, to evaluate the dependence of the output fluorescence intensity on both the promoter and the medium. The experimental setup conditions are the same for each test, and the OD value was mantained at 1.2. We took pictures of two fields from each of the five slides we prepared; then, we calculated the mean value for each slide and finally the mean and the standard deviation on these values. Here are the results:


LB M9
I763004 pLac-GFP 102.9 ± 13.4 123.2 ± 13.1
I763035 pTetR-LacI-GFP 106.6 ± 6.0 138.1 ± 7.7
I763011 Pλ-GFP 71.6 ± 12.3 81.3 ± 13.9

For complete results, see here.