Tokyo/Experimental precision and accurecy

From 2007.igem.org

(Difference between revisions)
 
(11 intermediate revisions not shown)
Line 1: Line 1:
 +
__NOTOC__
== AHL assay==
== AHL assay==
-
===Purpose1: ===
+
===Objective: ===
To see how precisely we determine the fluorescence from GFP by removing LB media.   
To see how precisely we determine the fluorescence from GFP by removing LB media.   
===Samples: ===
===Samples: ===
-
<br>placQI + GFP in pTrc99A (pos. con.)
+
placQI + GFP in pTrc99A (pos. con.)
<br>A4 ΔP+ GFP (neg. con.)
<br>A4 ΔP+ GFP (neg. con.)
Line 15: Line 16:
<br>(100:0), (70:30), (50:50), (30:70), (10:90), (3:97), (1:99)
<br>(100:0), (70:30), (50:50), (30:70), (10:90), (3:97), (1:99)
<br>[[Tokyo/Wash |Wash]]
<br>[[Tokyo/Wash |Wash]]
-
===Result: ===
+
===Result & conclusion: ===
-
===Conclusion: ===
+
In proportion to the percentages of GFP expressing cells, fluorescence was increased as shown in Fig. 1.
 +
<br>This indicates that the "[[Tokyo/Wash |wash]]" process well removes the other factors influencing the fluorescence.
 +
 
 +
== ==
 +
[[Tokyo/Preliminary assays |"Back to Preliminary assays"]]

Latest revision as of 18:48, 26 October 2007

AHL assay

Objective:

To see how precisely we determine the fluorescence from GFP by removing LB media.

Samples:

placQI + GFP in pTrc99A (pos. con.)
A4 ΔP+ GFP (neg. con.)

Procedure:


AHL assay Standard protocol
Make 200 ul of mixtures of pos. con. and neg. con.
The mixture ratios of pos. con. and neg. con. are
(100:0), (70:30), (50:50), (30:70), (10:90), (3:97), (1:99)
Wash

Result & conclusion:

In proportion to the percentages of GFP expressing cells, fluorescence was increased as shown in Fig. 1.
This indicates that the "wash" process well removes the other factors influencing the fluorescence.