Bologna University/Fluorescence reliance on Promoter and Medium
From 2007.igem.org
< Bologna University
Revision as of 15:22, 24 October 2007 by Guido Costa (Talk | contribs)
Fluorescence reliance on Promoter and Medium
We test bacteria with three different plasmids, [http://partsregistry.org/Part:BBa_I763004 I763004], [http://partsregistry.org/Part:BBa_I763035 I763035] and [http://partsregistry.org/Part:BBa_I763011 I763011], each of them into two different mediums, LB and M9, to evaluate the dependence of the output fluorescence intensity on both the promoter and the medium. The experimental setup conditions are the same for each test, and the OD value is mantained at 1.2. We take pictures from two spots on each of the five slides we prepare; then, we calculate the mean value for each slide and finally the mean and the standard deviation on these values. Here are the results:
LB | M9 | |
---|---|---|
I763004 | 102.9 ± 13.4 | 123.2 ± 13.1 |
I763035 | 106.6 ± 6.0 | 138.1 ± 7.7 |
I763011 | 71.6 ± 12.3 | 81.3 ± 13.9 |
For complete results, see here.