Imperial/Infector Detector/Modelling

From 2007.igem.org

(Difference between revisions)
(Discussion)
(Discussion)
Line 138: Line 138:
<br clear="all">
<br clear="all">
-
[[Image: Comparison transfer 50min.png|thumb|left|410px|'''Figure 4''': Comparison of constructs w.r.t their respective transfer functions, after t = 50min (x-axis is log-scaled)]]<br clear="all">
+
[[Image: Comparison transfer 50min.png|thumb|left|650px|'''Figure 4''': Comparison of constructs w.r.t their respective transfer functions, after t = 50min (x-axis is log-scaled)]]<br clear="all">
-
[[Image: Comparison transfer 200min.png|thumb|right|410px|'''Figure 5''': Comparison of constructs w.r.t their respective transfer functions, after t = 200min (x-axis is log-scaled)]]<br clear="all">
+
[[Image: Comparison transfer 200min.png|thumb|left|650px|'''Figure 5''': Comparison of constructs w.r.t their respective transfer functions, after t = 200min (x-axis is log-scaled)]]<br clear="all">
=== Conclusions ===
=== Conclusions ===

Revision as of 23:20, 24 October 2007



Infector Detector: Modelling

Abstract

Infector Detector (ID) is a simple biological detector, which serves to expose bacterial biofilm. It functions by exploiting the inherent AHL (Acetyl Homoserine Lactone) production employed by certain types of quorum-sensing bacteria, in the formation of such structures.
This section presents a preliminary model for an AHL detector, which employs the backbone of the Lux quorum-sensing feedback mechanism. Figures 1 and 2 illustrate the full system we are investigating.

In the design phase, two possible system constructs were proposed, as a solution to the problem of detecting AHL-producing biofilm. According to our specifications, the most crucial feature of this system is the sensitivity to a minimum [AHL] of 5nm. In other words, this represents the minimal AHL concentration for appreciable expression of a chosen reporter protein. Furthermore, we attempt to establish a functional range for possible AHL detection. How does increased AHL concentration impact on the maximal output of reporter protein? Finally, investigate how the system performance can be tailored, by exploiting possible inputs to the system (e.g. varying initial LuxR concentration and/or concentration of pLux promoters). In performing such customization, what is the impact upon the maximal output of fluorescent reporter protein and/or response time?

We attempt to answer these questions by establishing a representative model and consequently conducting a simulation of the system in-silico.

Implementation & Reaction Network

Figure 1: Reaction network for Construct 1
Figure 2: Reaction network for Construct 2


Representative Model

At reasonably high molecular concentrations of the state variables, a continuous model can be adopted, which is represented by a system of ordinary differential equations.

It is for this reason that our approach to modelling the system follows a deterministic, continuous approximation. In developing this model, we were interested in the behaviour at steady-state, that is when the system has equilibrated and the concentrations of the state variables remain constant.

We can condition the system in various manners, but for the purposes of our project, we will seek a formulation which is valid for both constructs considered, i.e. the governing equations are a represenation of both constructs.

The only difference is with regards to the parameter k1, the maximum transcription rate of the constitutive promoter (pTET) in Construct 1.
Thus k1 = 0 for construct 2 (which lacks pTET).

Our analysis took us through a number of models, but presented here is the most pertinent, most representative version. This model is based on energy-dependence (limited nutrient supply), which follows Hill-like dynamics.

The system kinetics are determined by the following coupled-ODEs. For a derivation of the governing equations, please access

Model 2, an energy-dependent network, where the dependence on energy assumes Hill-like dynamics



Model Parameters

Parameter Description
Kinetic
Constants
k1 Maximal constitutive transcription of LuxR by pTET
k2 Binding between LuxR and AHL
k3 Dissociation of protein complex LuxR-AHL (A)
k4 Binding between A and pLux promoter
k5 Dissociaton of A-pLux complex
k6 Transcription of FP
Degradation
Rates
δLuxR Degradation rate of LuxR
δAHL Degradation rate of AHL
δGFP Degradation rate of GFP
Hill Co-operativity
n Co-operativity coefficient describing the degree
of energy dependence, which follows Hill-like dynamics
Energy consumption
of transcription
α1 Energy consumption due to constitutive transcription of LuxR
α2 Energy consumption due to transcription of gfp gene


We now present the essential features of the system behaviour, simulated for a given set of parameters.

Simulations

Presented below are the most essential features of the simulation performed.

Figure 3: Comparison of the sensitivity, response time and maximal output of Construct 1 and Construct 2, , for varying initial [AHL]
i.e. AHL0 = 0, 0.1, 1, 5, 10, 100 & 1000 nM

Discussion

From figure 3, it is evident that the response time of construct 1 (C1) is far greater than that of construct 2 (C2). C1 crosses some arbitrary threshold, say 6000 a.u. at approximately t = 150min, whereas C2 below 10min. This is in line with our hypothesis, as we know steady-state has been forced upon the system in the case of construct 2 - by flooding the system with purified LuxR.

Secondly, the peak expression (max output) of GFP obtained for C1 is lower by approximately 50 percent. So, C2 produces a stronger output for corresponding [AHL]. However, although C2 is faster and generates a greater output, its energy consumption is far more pronounced. C1 thus has a greater lifespan.

Finally, in terms of sensitivity, construct 2 is also more sensitive to lower [AHL]; for the lowest [AHL] simulated, the peak output is 3 times greater than that of construct 1.


Figure 4: Comparison of constructs w.r.t their respective transfer functions, after t = 50min (x-axis is log-scaled)

Figure 5: Comparison of constructs w.r.t their respective transfer functions, after t = 200min (x-axis is log-scaled)

Conclusions

<< Design | Modelling | Implementation >>