Imperial/Infector Detector/Testing
From 2007.igem.org
(Difference between revisions)
m (→Aims) |
m (→Aims) |
||
Line 28: | Line 28: | ||
In addition the fluorescence measurements were converted to number of GFPmut3b molecules synthesised using a calibration curve constructed using purified GFPmut3b. | In addition the fluorescence measurements were converted to number of GFPmut3b molecules synthesised using a calibration curve constructed using purified GFPmut3b. | ||
+ | ===DNA Concentrations=== | ||
{|align="center" | {|align="center" | ||
| width="50%"|<br>[[Image:IC 2007 DNA Concentration.PNG|thumb|400px|Fig.1.1:Molecules of GFPmut3b synthesised over time, for each DNA Concentration ''in vitro'' - The fluorescence was measured over time for each experiment and converted into molecules of GFPmut3b ''in vitro'' | | width="50%"|<br>[[Image:IC 2007 DNA Concentration.PNG|thumb|400px|Fig.1.1:Molecules of GFPmut3b synthesised over time, for each DNA Concentration ''in vitro'' - The fluorescence was measured over time for each experiment and converted into molecules of GFPmut3b ''in vitro'' |
Revision as of 02:52, 26 October 2007
Infector Detector: Testing
Aims
The aims of the testing were as follows:
- To test and obtain the optimal DNA concentration for construct 1 in vitro
- To characterise the output of GFPmut3b for a range of AHL inputs. From this obtain the AHL sensitivity of our system.
In addition the fluorescence measurements were converted to number of GFPmut3b molecules synthesised using a calibration curve constructed using purified GFPmut3b.
DNA Concentrations
Results
The results show us the following:
|