Imperial/Cell by Date/Testing
From 2007.igem.org
m (→<font color=blue>Investigating properties of system under dynamic temperature scenarios</font>) |
m (→<font color=blue>Other Experiments</font>) |
||
Line 73: | Line 73: | ||
===<font color=blue>Other Experiments</font>=== | ===<font color=blue>Other Experiments</font>=== | ||
- | 1. DNA Concentration | + | 1. DNA Concentration : We conducted this experiment to tune our system, by varying the concentration of DNA in our cell extract,to realise the optimum performance of our pTet-GFPmut3b construct. We found that the optimum concentration of DNA is between 2-4µg on the basis of material cost and peak expression rate. For more information please click [https://2007.igem.org/Imperial/Wet_Lab/Results/Res1.8 here] |
- | 2. Packaging | + | 2. Packaging : We conducted this experiment to determine the effect of different packaging methods on the evaporation rate of our system. We found that out none of the packaging methods investigated decreased the rate of evaopration such that our system could survive for a week, as requested by our specifications. For more information please click [https://2007.igem.org/Imperial/Wet_Lab/Results/CBD2.1 here] |
Revision as of 01:56, 27 October 2007
Cell by Date: Testing
Summary
Key results of our experiments are :
1.Operating Range : Our System Operates between 8-37 Degrees
2.Activation Energy : The activation energy of our system is 1.5kJ/mol
3.Optimum DNA Concentration : The optimum DNA concentration for our system is 2-4ug DNA
Aims
Having determined that our system worked at a basic level in our implementation phase we set out to ascertain a clearer picture of the performance of our system to ultimately reveal whether our design had realised our specifications.
Results
Investigating properties of system under isothermal scenarios
To estimate the properties of our system we looked at the evolution of the Fluorescence with time for experiments where temperature is carefully kept constant. (Figure 1).
General Behaviour:
- In all experiment we can observe a linear growth of fluorescence corresponding to a steady rate of protein production.
- This matches the claims of the manufacturer of the cell-free extract that the extract is optimised so that protein degradation is negligible.
Operating Range:
- Our system seems to 'turn off' at around 4 degrees C.
- At 8 degrees with have minimal expression which then increases to a substantial expression at 37 degrees.
Synthesis rate vs Temperature
- Over the range of temperature considered here the rate increases with temperature.
- To investigate the relation between synthesis rate and temperature we extracted the rate of synthesis of GFP for each experiment and plotted it against 1/T (Figure 2).
- A strong linear correlation in the log plot supports an arrhenius type dependence on temperature with an activation energy of 1.5kJ/mol.
Need to put link here to wet lab page where i give full analysis of activation energy
Other practical considerations:
- Unfortunetly we have not been able to use a visible reporter and so have no idea whether the construct can in fact produce a visible signal.
- In terms of lifespan we have had major problems with evaporation meaning that the lifespan of our system is limited to a few days as discussed in our packaging experiment below.
Investigating properties of system under dynamic temperature scenarios
As per our specifications we are not only interseted in how our system behaves under isothermal scenarios but also under dynamic temperature scenarios representative of a break in the cold chain for example.
Below in figure 3 are the results from one of our experiments in which we subjected our system to a number of steps.
General Behaviour :
- Step Down from 20 to 4 Degrees : Rate of fluoresence decreases in comparison to the 20 degree isothermal curve. This is a positive result as it correlates with Koutsoumanis' meat model in our modelling section.
- Step Up from 4 to 20 Degrees : Rate of fluoresence increases rapidly in comparison to the 20 degree isothermal curve. This is a positive result as it correlates with Koutsoumanis' meat model in our modelling section in which the response time of spoilage bacteria in beef is very small.
Other Experiments
1. DNA Concentration : We conducted this experiment to tune our system, by varying the concentration of DNA in our cell extract,to realise the optimum performance of our pTet-GFPmut3b construct. We found that the optimum concentration of DNA is between 2-4µg on the basis of material cost and peak expression rate. For more information please click here
2. Packaging : We conducted this experiment to determine the effect of different packaging methods on the evaporation rate of our system. We found that out none of the packaging methods investigated decreased the rate of evaopration such that our system could survive for a week, as requested by our specifications. For more information please click here