Imperial/Dry Lab/Modelling

From 2007.igem.org

< Imperial | Dry Lab(Difference between revisions)
 
(68 intermediate revisions not shown)
Line 1: Line 1:
-
=Model Development for Infector Detector=
+
{{Template:IC07navmenu}}
 +
<br clear="all">
 +
__TOC__
-
==Formulation of the problem==
+
<center>'''Welcome to the Modelling Sub-Portal Page'''</center><br><br>
-
As described earlier, catheter-associated urinary tract infection (CAUTI) in the clinical setting is a prevalent problem with extensive economic impact. The underlying cause of many such infections can be attributed to the formation of biofilm, by aggregating-bacteria on the surface of urinary catheters.
+
<center>This page serves as a shuttle to the modelling phase of each project:Infector Detector and Cell-by-Date. </center>
 +
----
-
[[Image: IC07_QS.png|right|thumb|500px| Role of AHL (HSL) quorum-sensing in biofilm formation]]
+
<center>Select one of the following links to be transferred to the modelling of the relevant project.</center>
-
Infector Detector (ID) is a simple biological detector, which serves to expose bacterial biofilm. It functions by exploiting the inherent AHL (Acetyl Homoserine Lactone)  production employed by certain types of quorum-sensing bacteria, in the formation of such structures.<br>
 
-
Our project attempts to improve where previous methods of biofilm detection have proven ineffective: first and foremost, by focussing on the sensitivity of the system, to markers of biofilm: in this case, low levels of AHL production (which represents the bacterial "chatter" of such aggregating bacteria).
+
{| border="0" width="80%" align="center"
 +
|- align="center"
 +
||
 +
{{Click || image = ID ModelPage.jpg| link = Imperial/Infector_Detector/Modelling | width = 200px | height = 198px }}
 +
<br> [[Imperial/Infector_Detector/Modelling| '''Infector Detector''']]
 +
||
 +
{{Click || image = ThermoDA.jpg| link = Imperial/Cell_by_Date/Modelling | width = 200px | height = 200px }}<br>
 +
[[Imperial/Cell_by_Date/Modelling| '''Cell-by-Date''']]
 +
|}
 +
<br clear="all">
-
In doing so, a complete investigation of the level of sensitivity to AHL concentration needs to be performed - in other words, what is the minimal AHL concentration for appreciable expression of a chosen reporter protein. Furthermore, establish a functional range for possible AHL detection. How does increased AHL concentration impact on the maximal output of reporter protein?<br>
 
-
Finally, how can the system performance be tailored, by exploiting possible state variables (e.g. varying initial LuxR concentration and/or concentration of pLux promoters). 
 
-
The system performance here revolves most importantly around AHL sensitivity; however, the effect on the maximal output of fluorescent reporter protein and response time is, likewise, of great importance.
+
<center> | [[Imperial/Dry_Lab | Dry Lab >>]]</center>
-
 
+
-
==Selection of Model Design and Structure==
+
-
 
+
-
Since the novelty of our solution revolves around the use of cell-free systems as a "bacterial-free" solution in the clinical setting, a simple system is selected. Our approach involves a modified version of the bioluminescence machinery employed by the bacterium ''Vibrio Fischeri''.
+
-
 
+
-
In fact, the characterization of this machinery, forms the setting for the first detailed description of the above-mentioned quorum-sensing phenomenon (Engebrecht and Silverman, 1984 and Engebrecht et al., 1983).
+
-
A system which employs two regulatory proteins LuxR and LuxI, which, together with the autoinducer protein, AHL, control the expression of the in-house reporter (luciferase).
+
-
 
+
-
Our system maintains the general flavour of this configuration; involving a marginally-varied sensor and reporter element.
+
-
In fact, an already present system is utilized, for its simplicity and good definition - [http://partsregistry.org/Part:BBa_T9002| T9002]. This forms our construct 1.
+
-
 
+
-
One of the questions posed in the formulation of the model, involved exploring means of "tweaking" the system to achieve improved performance (sensitivity/maximal output/response time). A possible solution could involve introducing purified LuxR into the system, and in this way impose steady-state far sooner than construct 1. Theoretically, this should shorten response time. It is for this reason, that a second construct will be investigated. Construct 2 thus differs only wrt the elimination of the constitutive promoter pTET. (here, LuxR is introduced directly).
+
-
 
+
-
<font color = red>~~Insert diagram illustrating both constructs </font><br>
+
-
 
+
-
<font color = red>~~Insert diagram illustrating both interaction of molecules </font><br>
+
-
 
+
-
==Establishing a model==
+
-
 
+
-
===Approach===
+
-
 
+
-
==References==
+
-
 
+
-
==Motif==
+
-
*Images - black borders, pastel backgrounds (pale) - see QS image
+

Latest revision as of 02:10, 27 October 2007



Welcome to the Modelling Sub-Portal Page


This page serves as a shuttle to the modelling phase of each project:Infector Detector and Cell-by-Date.

Select one of the following links to be transferred to the modelling of the relevant project.



Infector Detector


Cell-by-Date



| Dry Lab >>