Imperial/Infector Detector/Conclusion

From 2007.igem.org

(Difference between revisions)
(Battle a spectrum of infections)
(Battle a spectrum of infections)
Line 31: Line 31:
<br>
<br>
-
[[Image:IC2007 conclusion2.jpg|170px|left|]]                   
+
[[Image:IC2007 conclusion3.jpg|170px|left|]]                   
-
[[Image:IC2007 conclusion1.jpg|540px|left|]][[Image:IC2007 conclusion3.jpg|170px|right|]]
+
[[Image:IC2007 conclusion1.jpg|540px|left|]][[Image:IC2007 conclusion2.jpg|170px|right|]]
<br clear="all">
<br clear="all">
<br><br>
<br><br>

Revision as of 01:23, 25 October 2007




Future Work

Battle a spectrum of infections


The great potential of Infector detector is that it is not limited to just one infection. Adding sensitivity to AHL originating from biofilms is just the beginning. By tweaking the internal mechanisms of the construct, Infector Detector can be used to battle a range of catheter-related bacteremias. For example by using a construct that recognises AI-2 (autoinducer 2), we can detect the presence of Klebsiella pneumoniae, a pathogenic bacterium ranked second to E. coli for urinary tract infections in older persons.

IC2007 conclusion3.jpg
IC2007 conclusion1.jpg
IC2007 conclusion2.jpg




Added control - Construct 2


The main advantage of using construct 2 (ADD LINK HERE) is that it provides an additional control mechanism for our detector meaning that you can tweak the detector sensitivity.
Going into deeper detail, construct 1 can produce LuxR as soon as it is activated. LuxR's presence is necessary for the formation of AHL-LuxR complex and the subsequent activation of pLux (leading to GFP production). Construct 2 on the other hand does not have a LuxR producing part. It relies on the user to add the necessary LuxR to form the binding complex. This control over LuxR can thus act as a sort of attenuator to the sensitivity of Infector Detector.
Having little LuxR present, will form very little binding complex with AHL and thus the sensitivity will decrease significantly. Saturating the detection compound with LuxR will maximise the sensitivity. Briefly, if we want to detect only highly progressed infections, we add little LuxR. If we want to detect infections with minimum progression, we saturate with AHL.
Thus construct 2 can be used as a sensitivity attenuator.

Tweaking sensitivity using LuxR




Packaging

Infector Detector can be packaged into either a cream or a spray.


Infector Detector Spray



A spray will provide easy application of the detector because it does not require the user to fiddle around with the urinary catheter as he can simply spray from a distance. The disadvantage being poor accuracy of application and more evaporation.

Infector Detector Creme


A cream on the other hand will decrease significanlty any evaporation and will allow the user to apply the detector to specific areas of the catheter without the possibility of spraying the patient itself with detector. The disadvantage being here is the low diffusion rates of AHL and other compounds that need to cross the viscous cream to reach the actual detector assemblies. This might hinder rapid detection.



Both applications provide some advantages and disadvantages that must be weighed depending on the actual use scenario of Infector Detector in order to decide which is best.




<< Testing | Conclusions | Home >>