Imperial/Wet Lab/Lab Notebook/2007-10-05

From 2007.igem.org

< Imperial | Wet Lab | Lab Notebook(Difference between revisions)
m
 
(2 intermediate revisions not shown)
Line 5: Line 5:
 +
==pTet-LuxR-pLux-GFP construct in-vivo==
 +
*'''Aim''': The aim of the test was to check if construct 1 of infector detector works in-vivo
 +
*The protocols for the experiment can be found in the [[Imperial/Wet_Lab/Protocols/ID1.1|Protocols page]]
 +
*The [[Imperial/Wet_Lab/Results/ID1.1|results]] of the test showed that pTet-LuxR-pLux-GFPmut3b is working in vivo and GFPmut3b produced increases with increasing [AHL]
 +
 +
==pTet-LuxR-pLux-GFP construct in-vitro==
 +
*'''Aim''': The aim of the test was to check if construct 1 of infector detector works in-vitro, for a number of concentrations of AHL
 +
*The [[Media:IC 2007 PLux in-vitro 05-10 25oC.xls|results]] of the test seemed very variable and didn't seemed to comply with the tests that were carried out before. There was a lot of variability between the samples and 4nM of AHL seemed to have fluorescence output greater than 50nM.
 +
*It was decided to carry out the experiment again. The reasons for the inaccuracies in the data could have been:
 +
**The reaction was not mixed properly or the right amounts were not pipetted
 +
**The plates had already been used and thus could have affected the reaction
<html></div></html>
<html></div></html>
{{Template:IC07labnotebook}}
{{Template:IC07labnotebook}}

Latest revision as of 18:49, 26 October 2007

5 October 2007

pTet-LuxR-pLux-GFP construct in-vivo

  • Aim: The aim of the test was to check if construct 1 of infector detector works in-vivo
  • The protocols for the experiment can be found in the Protocols page
  • The results of the test showed that pTet-LuxR-pLux-GFPmut3b is working in vivo and GFPmut3b produced increases with increasing [AHL]

pTet-LuxR-pLux-GFP construct in-vitro

  • Aim: The aim of the test was to check if construct 1 of infector detector works in-vitro, for a number of concentrations of AHL
  • The results of the test seemed very variable and didn't seemed to comply with the tests that were carried out before. There was a lot of variability between the samples and 4nM of AHL seemed to have fluorescence output greater than 50nM.
  • It was decided to carry out the experiment again. The reasons for the inaccuracies in the data could have been:
    • The reaction was not mixed properly or the right amounts were not pipetted
    • The plates had already been used and thus could have affected the reaction