Imperial/Wet Lab/Lab Notebook/2007-10-10
From 2007.igem.org
(Difference between revisions)
Line 5: | Line 5: | ||
+ | ==Media test== | ||
+ | *The '''aim''' of this test was to see if the fluorescence of GFP mut3b gets affected by the media it is in. | ||
+ | *We tested the reporter's expression in nuclease free water and LB media and then compared it with the reults got from GFP mut3b calibration curve | ||
+ | *The results can be found [[Media:IC 2007 Mediatest.xls|here]] | ||
+ | *It was found a linear relationship between the fluorescence of GFP mut3b in the three media. | ||
+ | *This meant that LB media could be used to get calibration curve for dsRED express instead of cell extract. But as dsRED express couldn't be cloned, we didn't make a calibration curve for dsRED express | ||
+ | |||
+ | ==pT7 test in-vitro== | ||
+ | *The '''aim''' of the test was to see if pT7-GFP mut3b and pT7-dsRED express work in-vitro or not | ||
+ | *The protocols can be found [[IGEM:here|here]] | ||
+ | *The experiment didn't give good results as: | ||
+ | **The incubator had been turned off, thus the samples were not at the right temperature. | ||
+ | **The right filter for dsRED express was not used to begin with | ||
+ | *After using the right filter, it was realised that pT7-dsRED express construct doesn't express | ||
+ | *The results can be found [[IGEM:here|here]] | ||
<html></div></html> | <html></div></html> | ||
{{Template:IC07labnotebook}} | {{Template:IC07labnotebook}} |
Revision as of 19:44, 24 October 2007
10 October 2007
Media test
- The aim of this test was to see if the fluorescence of GFP mut3b gets affected by the media it is in.
- We tested the reporter's expression in nuclease free water and LB media and then compared it with the reults got from GFP mut3b calibration curve
- The results can be found here
- It was found a linear relationship between the fluorescence of GFP mut3b in the three media.
- This meant that LB media could be used to get calibration curve for dsRED express instead of cell extract. But as dsRED express couldn't be cloned, we didn't make a calibration curve for dsRED express
pT7 test in-vitro
- The aim of the test was to see if pT7-GFP mut3b and pT7-dsRED express work in-vitro or not
- The protocols can be found here
- The experiment didn't give good results as:
- The incubator had been turned off, thus the samples were not at the right temperature.
- The right filter for dsRED express was not used to begin with
- After using the right filter, it was realised that pT7-dsRED express construct doesn't express
- The results can be found here